Cooling Systems
Rooftop units, chillers and cooling towers, condensing units, and VRF systems. Seasonal start-ups, refrigerant leak detection, and capital equipment upgrades.
- All major RTU manufacturers serviced
- Air-cooled and water-cooled chiller plants
- VRF / VRV diagnostics and commissioning support
Cooling equipment represents some of the largest mechanical investments in a commercial building, and it fails at the worst possible time: when it is working hardest. Woola provides commercial cooling service across Metro Vancouver, from packaged rooftop units to chiller plants, with a focus on preventative maintenance, accurate diagnostics, and well-planned capital upgrades.
Our approach is straightforward. Maintain the equipment properly, catch refrigerant and component issues early, and give you a clear picture of remaining service life so replacement is a planned project instead of a summer emergency.
Commercial cooling services
- Rooftop unit (RTU) service and maintenance
- Chiller and cooling tower service
- Condensing unit service and repairs
- VRF and VRV systems
- Seasonal start-up and shutdown
- Refrigerant leak detection and repairs
- HVAC controls and performance optimization
- Equipment retrofits and capital upgrades
- Preventative maintenance programs
- Emergency cooling repairs
Rooftop unit (RTU) service and maintenance
RTUs are the most common commercial HVAC equipment in the region, packaging heating, cooling, ventilation, and air distribution into a single unit that sits exposed to the weather all year. That exposure takes a toll. We service RTUs from all major manufacturers, covering maintenance, diagnostics, repairs, component replacement, and upgrades.
A proper RTU visit goes deeper than a filter change. Our technicians inspect compressors, motors, belts, bearings, coils, economizers, dampers, electrical connections, controls, and refrigerant circuits, because most RTU failures start as small mechanical or electrical issues that a thorough inspection catches.
Chillers and cooling towers
In larger buildings, the chiller plant is the backbone of cooling, supplying chilled water for air conditioning and process loads. We provide maintenance, repairs, diagnostics, replacements, and modernization for both air-cooled and water-cooled chillers, along with the cooling towers, condenser water systems, pumps, heat exchangers, and controls that support them. Treating the plant as one system is what keeps efficiency where it should be.
Condensing units
Condensing units do the unglamorous work of rejecting heat for air conditioning and refrigeration systems, and outdoor exposure to dirt, debris, and weather steadily erodes their performance. Our service includes inspections, maintenance, repairs, refrigerant diagnostics, coil cleaning, electrical testing, and component replacement.
VRF and VRV systems
VRF and VRV systems deliver efficient zoned heating and cooling, but their sophisticated controls and refrigerant management demand specialized knowledge. We provide maintenance, commissioning support, diagnostics, repairs, leak detection, controls troubleshooting, and upgrades for these systems.
Seasonal start-up and shutdown
Cooling equipment that sat idle all winter deserves a proper start-up before the first hot week, and a proper shutdown protects it through the off-season. Both are scheduled visits with documented findings, so surprises get caught in April rather than July.
Book the spring visit before the heat wave books it for you
Every summer, buildings that skipped start-up inspections join the repair queue at its longest. A maintenance program keeps your cooling equipment ahead of the season and keeps your tenants out of the heat.
Request service
Describe the building and what's happening. A coordinator scopes the visit before anyone rolls a truck.
604-732-1441Equipment we service.
Each unit links to a plain-English walkthrough of what it does, what fails, and what to keep an eye on.

Rooftop Unit (RTU)
A packaged heating and cooling box that sits on the roof and conditions the floors below. Most commercial buildings run several, each serving its own zone.
- ·Uneven temperatures between zones
- ·Short cycling or constant running
- ·Rising energy bills with no usage change
- Quarterly filter changes and coil cleaning
- Belt, bearing, and economizer checks each season
- Refrigerant charge verified annually

Cooling Tower
Rejects building heat to the outdoors using evaporating water. Paired with chillers or water-source heat pump loops in larger buildings.
- ·Loop temperatures creeping up
- ·Scale or algae visible in the basin
- ·Drift or splash-out on the roof
- Water treatment program, verified monthly
- Basin cleaning and fill inspection
- Fan and drive service each season

Compressor
The pump at the heart of every AC, heat pump, and refrigeration system. When a quote says 'replace compressor,' this is the part doing the pushing.
- ·Hard starts, clicks, or tripped breakers
- ·Warm air from a system that should cool
- ·Oil stains around the unit
- Refrigerant charge and superheat checked annually
- Electrical connections tightened and tested
- Vibration and amp-draw trending
Recent projects.
RepipingResidential Copper & Poly-B Repiping in Occupied Buildings
Cooling plant120-Ton Modular Chiller Plant Replacement
ElectrificationAll-Electric Domestic Hot Water Plant Conversion






How we handle it.
- All major RTU manufacturers serviced
- Air-cooled and water-cooled chiller plants
- VRF / VRV diagnostics and commissioning support
- Emergency cooling repairs
RTUs, chillers, VRF across Whistler, Squamish, West Vancouver, North Vancouver, Vancouver, Burnaby, and 12 more municipalities.
Book cooling systems with Woola.
Tell us about the property and we'll get a coordinator in touch within one business day.
24/7 emergency dispatch for contracted clients